NH3 Gas Leakage - Detection

Product Series: HBGS

HBGS fulfils the requirements for gas leakage measurement in accordance with F-GAS regulation EU/517/2014. HBGS exists in two versions and detects NH3(R717) in a range of 0-1000 ppm or 0-5000 ppm. It is an independent unit that must be supplied with 24 V DC. It has 3 built-in digital alarm outputs and one analog 4-20 mA output. The sensor can be set up using a PC with the HB Configuration Tool. The sensor element has a lifetime of 2 years and can easily be replaced. On the front, you can find 4 integrated LEDs for display of the supply (green) as well as 3 alarm levels (red, orange, and yellow). Similarly, there is a reset button in case an alarm is triggered. The sensor is factory calibrated and comes with a calibration certificate as well as preconfigured alarm limits. Verification during the lifetime can be done with high gas concentrations. The sensor can be used in areas where cleaning solvents are used. A built-in heating element ensures the functionality down to -30 ° C ambient temperatures.


Product features

  Integrated LED's for display of the supply (green) as well as 3 alarm levels (red, orange and yellow).
  The sensor is factory calibrated and does not require additional calibration at startup. The sensor comes with a calibration certificate as well as with configured alarm limits.
  Signal output for alarm light.

Specifications

Electrical installation

HBGS web 

Drawing

 HBGS NH3 KOMP R3 1 Small

 

 
Power supply
Power supply24 V DC - Power consumption max 3 watt
ConnectionScrew terminals
Cable glands2 x PG7
AlarmCan be configured with HB Tool and an USB cable and an adapter
Alarm limits0 to 1000 ppm or 0 to 5000 ppm for NH3
Measurement accuracy NH3Repeatability +/-10%
Analog output4...20 mA
Max load500 ohm
Alarm output, relay3 x SPDT, 0,5A
Environmental conditions
Ambient temperature-30...+50°C
Protection degreeIP20, box IP65
Mechanical specifications
Cabinet size82x59x126 
MaterialPlastic
MountingOn walls with screws
Approvals
EMC EmissionEN 61000-6-4
EMC EmissionEN 61000-6-2
Accessories
Alarm device - part number Sounder Beacon
Alarm  can be configured with HB Tool
Alarm limits0 to 1000 ppm or 0-5000 ppm for NH3
Alarm A800 ppm for NH3 (Main alarm acc. to EN378)
Alarm B500 ppm for NH3 (Pre-alarm acc. to EN 378)
Alarm C200 ppm for NH3 (Pre-alarm acc. to EN 378)

Ordering code

0...1000 ppmNH3 (R717)HBGS-NH3 0...5000 ppmNH3 (R717)HBGS-NH3-5000PPM AccessoriesGasOrdering code Part no. Service kit for verificationNH3 (R717)HBGS-ServiceKit Part no. Sounder/flash lightNH3 (R717)Sounder Beacon